4000-520-616
欢迎来到免疫在线!(蚂蚁淘生物旗下平台)  请登录 |  免费注册 |  询价篮
主营:主营:分子类,蛋白类,抗体类,生化类试剂
咨询热线电话
4000-520-616
当前位置: 首页 > 产品中心 > peptide > Nexcelom Bioscience/细胞计数/活性试剂| Nexcelom Bioscience/200 uL/CS2
商品详细Nexcelom Bioscience/细胞计数/活性试剂| Nexcelom Bioscience/200 uL/CS2
Nexcelom Bioscience/细胞计数/活性试剂| Nexcelom Bioscience/200 uL/CS2
Nexcelom Bioscience/细胞计数/活性试剂| Nexcelom Bioscience/200 uL/CS2
商品编号: CS2
品牌: nexcelom
市场价: ¥0.00
美元价: 0.00
产地: 美国(厂家直采)
公司:
产品分类: 多肽合成
公司分类: peptide
联系Q Q: 3392242852
电话号码: 4000-520-616
电子邮箱: info@ebiomall.com
商品介绍

Cell Counting / Viability Reagents

Instrument Compatibility for Cell Counting / Viability Reagents

Auto 2000Auto X4X1X2K2Vision CBACeligo
ViaStain™ AOPI Staining Solution X XX XX X
ViaStain™ AO Staining Solution XXXXXX
ViaStain™ PI Staining SolutionXXXX XXX
ViaStain™ Calcein AM XXX XX X
ViaStain™ Calcein AM / PI Cell Viability Kit XX XX X
ViaStain™ Calcein AM / Hoechst / PI Cell Viability Kit X
DAPIX X
Hoechst 33342X X
ViaStain™ Hoechst/PI Viability KitX X
Ask a Specialist
Shop Online
View All Reagents

ViaStain™ AO / PI Viability Stains

AO/PI Staining Solution: For accurate determination of live / dead nucleated cell concentration in heterogeneous samples using dual-fluorescence.

Dual-Fluorescence Viability, using acridine orange (AO) and propidium iodide (PI), is the recommended method for accurate viability analysis of primary cells, such as PBMCs, splenocytes, and stem cells in samples containing debris and unwanted non-nucleated cell types including red blood cells.

Acridine orange (AO) and propidium iodide (PI) are nuclear staining (nucleic acid binding) dyes. AO is permeable to both live and dead cells and stains all nucleated cells to generate green fluorescence. PI enters dead cells with compromised membranes and stains all dead nucleated cells to generate red fluorescence. Cells stained with both AO and PI fluoresce red due to quenching, so all live nucleated cells fluoresce green and all dead nucleated cells fluoresce red.

Because mature mammalian red blood cells do not contain nuclei, only live and dead mononuclear cells produce a fluorescent signal. There is no need to lyse red blood cells, saving time and eliminating an extra sample preparation step.

For AO/PI staining and viability determination, 20 µl of live cell sample and 20 µl of AO/PI Staining Solution are combined. 20µl of stained sample is then added to a Cellometer Counting Chamber and analyzed in <60 seconds using a fluorescent Cellometer instrument. Each instrument automatically reports live / dead cell number, live/dead cell concentration, mean diameter, and percent viability for the sample tested.

Exclude red blood cells from countRed blood cells seen next to the arrows in the bright field image (above left) do not appear in the fluorescent image (above right).
AO/PI method live cell image

ViaStain™ AO/PI Staining Solutions

DescriptionCatalog NumberUnit SizeManualSDS
AO/PI (acridine orange / propidium iodide) staining solution for live/dead Mammalian nucleated cells.CS2-0106-5mL

CS2-0106-25mL

5 mL

25 mL

pdfUS:AOPI

EU:AOPI

Buy Online

Buy Online

AO (acridine orange) staining solution for staining of nucleated cells.CS1-0108-5mL5 mLpdfUS:AO

EU:AO

Buy Online
PI (propidium iodide) staining solution for staining of dead nucleated cells.CS1-0109-5mL5 mLpdfUS:PI

EU:PI

Buy Online

ViaStain™ Calcein AM

Calcein AM stained cell image

Calcein AM (Calcein acetoxymethyl ester) is a cell permeable, non-fluorescent compound. Upon crossing the cell membrane, calcein-AM is rapidly hydrolyzed by cellular esterases inside live cells. The hydrolysis cleaves the AM group, converting the non-fluorescent calcein AM to a strongly green fluorescing calcein. Because the created calcein is more hydrophilic it is trapped inside the cells with intact membranes. Cells that do not possess active cytoplasmic esterases are unable to convert calcein AM to calcein, and therefore do not fluoresce green. This allows for a quick and easy detection of metabolically-active cells in a sample.

Since calcein-AM does not require DNA binding, it stains all metabolically-active cells and can be used to measure metabolic activity in non-nucleated cells, such as platelets. Because calcein AM is photostable, has low cytotoxicity and does not affect cellular functions, it is a popular stain for the examination of cell vitality and metabolic activity.

ViaStain™ Calcein AM

DescriptionCatalog NumberUnit SizeManualSDS
Cell permeable viability dye. In live cells, non-fluorescent Calcein AM is converted by cellular esterases into green fluorescing cells.CS1-0119200 uLpdfUS:CalceinEU:CalceinBuy Online

ViaStain™ Calcein-AM / PI Cell Viability Kit

Calcein-AM/PI Cell Vitality and Viability kit

The Nexcelom Calcein-AM/PI Cell Vitality and Viability kit enables measurement of the number and concentration of both metabolically active and dead, or non-viable, cells in a population. The software automatically calculates percent vitality/viability based on the number of Calcein-positive (metabolically active) cells, and the number of PI-positive (non-viable) cells.

Assay Principle

Acetoxymethyl ester of calcein (calcein-AM) is a non-fluorescent dye that passively enters cells. In metabolically active cells, the dye is converted by cytosolic esterases into green fluorescent calcein. The fluorescent calcein is retained by cells with intact membranes. Metabolically-active cells fluoresce in the green channel. Propidium iodide (PI) is a DNA-binding dye that enters cells with compromised membranes. Dead (compromised) nucleated cells fluoresce in the red channel.

ViaStain™ Calcein AM / PI Cell Viability Kit

DescriptionCatalog NumberUnit SizeManualSDS
The Calcein-AM/PI Cell Vitality and Viability kit enables measurement of the number and concentration of both metabolically active calcein positive and dead PI positive cellsCSK-0118pdfUS:CalceinEU:CalceinUS:PIEU:PIBuy Online

ViaStain™ Calcein AM / PI / Hoechst Viability Kit

Calcein AM / PI / Hoechst Viability Kit

Calcein AM (Calcein acetoxymethyl ester) is a cell-permeable, non-fluorescent compound. Upon crossing the cell membrane, calcein AM is rapidly hydrolyzed by cellular esterases inside live cells. The hydrolysis cleaves the AM group, converting the non-fluorescent calcein AM to a strongly green fluorescing calcein. The more hydrophilic calcein is trapped inside the cell. Cells that do not possess active cytoplasmic esterases are unable to convert calcein AM to calcein, and therefore do not fluoresce green. This allows for a quick and easy detection of metabolically-active cells in a sample.

When Calcein AM is used in conjunction with PI, it is possible to determine % vitality/viability based on the number of metabolically-active (green fluorescent) and non-viable (red fluorescent) cells in a sample. To enumerate the total number of nucleated cells, the cells were counterstained with Hoechst 33342.

converting calcein AM to calcein

ViaStain™ Calcein AM / Hoechst / PI Cell Viability Kits

DescriptionCatalog NumberUnit SizeManualSDS
Cell viability kit contains three reagents: Calcein AM, Hoechst and PI. Live and metabolically active cells are labeled with Calcein, dead cells are labeled with PI, and total number of cells is determined by Hoechst.

CSK-V0006-1 replaces the discontinued CSK-V0001-1 offering.
CSK-V0006-1pdfUS:CalceinEU:CalceinUS:PIEU:PIUS:HoechstEU:HoechstBuy Online

DAPI

DescriptionCatalog NumberUnit SizeManualSDS
DAPI is a fluorescent dye that binds to DNA. Excited by UV light, and may be used to stain live and fixed cells.CS1-0127-2mL2 mLpdfUS:DAPIEU:DAPIBuy Online

Hoechst 33342

DescriptionCatalog NumberUnit SizeManualSDS
Hoechst 33342 is a fluorescent dye, excited by UV light, that binds to DNA. Hoechst 33342 is more lipophilic than other Hoechst dyes and therefore can enter live cells more easily.CS1-0128-5mL5 mLpdfUS:HoechstEU:HoechstBuy Online

ViaStain™ Hoechst/PI Viability Kit

DescriptionCatalog NumberUnit SizeManualSDS
A no wash assay kit designed to determine cell viability by staining dead cells with PI and all cell with Hoechst 33342.CSK-V0005-1pdfUS:PIEU:PIUS:HoechstEU:HoechstBuy Online
品牌介绍
美国Nexcelom Bioscience LLC www.nexcelom.comCellometer Model Auto T4细胞计数器的大小仅为3.5x4英寸。可丢弃的计数室由质量保证的塑料制成。样品加入小室后,放置在Auto T4上,经过USB数据线与电脑连接。成像软件能够自动测量细胞的浓度和变化。在异源性样品中的细胞即使具有不同的大小和形态学特征,也同样能够被测量。可丢弃的小室也排除了清洗的步骤,可以防止交叉污染和堵塞。